PRODUCTS LIST

Gate valve
Butterfly valve
Ball valve
Globe Valve
Check valve
Control valve
Water Meter
Air valve
Copper valve
Pipe Repair & Coupling
Ductile iron(DI) pipe fittings
Strainer
Dismantling Joint

Ultrasonic flow meter installation method

2022-03-28
 1.W-method Installation

W-method is usually used on plastic pipes with a diameter from 15mmto 100mm;

2. V-method Installation

V-method installation is the most widely used mode for daily measurement with pipe inner diameters ranging from 15 mm to 200 mmIt is also called reflective mode.

3.Z-method Installation

Z-method is commonly used when the pipe diameter is between 300mmand 500mm;